5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD

기본 특성
원산지: 심천, 중국 (본토)
브랜드 이름: ESTEL
인증: ISO9001, CE, 3C, FCC
부동산 거래
최소 주문 수량: 1
가격: 987-2327 usd
지불 조건: L/C, D/A, D/P, T/T, 서부 동맹
공급능력: 달 당 2,500개 세트
제품 요약
5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD Introduction of ET48300 18KW DC48V Telecom Power Supply The ET48300-005 is a smart high efficient telecom rectifier system that engineered for demanding applications, such as telecom base stations (including 4G ...

제품 상세정보

강조하다:

5G telecom base station power supply

,

18kw DC power system

,

Telecom rectifier system with LLVD BLVD

Type: 전기통신 직선화 시스템
AC Input: 220VAC 단상
DC Output: DC48v
Output Capacity(Max): 18kw(N+1 이중화)
Rectifier Module: 3000w x 6
Mounting: 19인치 랙 마운트
Remote Control:
Communication: RS485/SNMP/LAN
제품 설명

5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD

 

Introduction of ET48300 18KW DC48V Telecom Power Supply

 

The ET48300-005 is a smart high efficient telecom rectifier system that engineered for demanding applications, such as telecom base stations (including 4G and 5G), data centers. The DC Rack Power System accepts 220VAC single phase input, and delivers a resilient, high-capacity DC power of higher than 96% efficiency, providing a stable, adjustable output from –43VDC to –58VDC (typically –53.5VDC). The system adopts 6*3000w rectifier module and N+1 redundancy design, and can power telecom equipment with a maximum of 18kw output, and Its industrial-grade standard and forced cooling allow it to be used in various environments.

 

This telecommunication power supply is equipped with a comprehensive tiered load protection mechanism on the DC output side. By configuring LLVD (Low Voltage Load Disconnect), BLVD (Battery Low Voltage Load Disconnect), and BATT (Battery) circuit breakers, the system enables precise control over loads with different priority levels.

 

 

LLVD of ET48300 18KW DC48V Telecom Power Supply

 

For LLVD (Low Voltage Load Disconnect) , the system provides a total of 7 output branches: two 32A/1P, two 40A/1P, and three 63A/1P. These branches are used for non-critical loads that can be temporarily interrupted. When the battery voltage drops to a preset threshold, the LLVD automatically disconnects these circuits first, reserving the remaining battery capacity for core communication equipment and effectively extending the runtime of critical services.

5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD 0

 

BLVD of ET48300 18KW DC48V Telecom Power Supply

 

For BLVD (Battery Low Voltage Load Disconnect) , the system is configured with six smaller-capacity output branches: two 6A/1P, two 10A/1P, and two 16A/1P. These are dedicated to the most critical loads, such as communication transceivers, controllers, or transmission units. The BLVD threshold is set lower than the LLVD threshold, meaning these circuits are disconnected only when the battery voltage drops to a critically low level. This design maximizes the continuity of essential communication services under extreme power conditions. The system is also equipped with two 125A/1P battery circuit breakers for connecting backup battery banks.

5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD 1

 

Maintenance of ET48300 18KW DC48V Telecom Power Supply

 

This rectifier power supply adopts a top-in and top-out cabling design. This design means that only a small space needs to be left behind the power supply for heat dissipation, and no need big space for cables. Maintenance can be carried out directly from the front of the cabinet without adding a cabinet door. This greatly saves cabinet space and reduces the size and cost of the cabinet.

 

Power Distribution of ET48300 18KW DC48V Telecom Power Supply

 

AC
Distribution

Input mode

 

Single phase 220V 1*63A/2P
Input frequency 45~65Hz, rated value: 50Hz/60Hz
AC SPD 20kA/40kA, 8/20μs
DC
Distribution
Output voltage -43~-58VDC, rated value: -53.5VDC
Maximum capacity 18kw(6*3kw, N+1 redundancy)
Battery breakers 2*125A/1P
Load breakers

LLVD: 32A/1P*2 + 40A/1P*2 + 63A/1P*3

BLVD: 6A/1P*2 + 10A/1P*2 + 16A/1P*2

DC SPD 10kA/20kA, 8/20μs
Rectifier Module Input voltage 85VAC~300VAC, rated 220VAC
  Efficiency >96%
  Rated power 3000W(176~300VAC)
  Power factor ≥0.99
  THD ≤5%
  DC output –43 ~ –58VDC, rated –53.5VDC, maximum 55A

 

 

Application Scenarios

 

4G/5G Telecom Base Stations

Remote & Harsh Environment Sites

Industrial Communication Systems

Microwave and Optical Fiber Repeater Stations

 

5G Telecom Base Station DC Power System 18kw Load Protection Power Supply with LLVD BLVD 2

관련 상품
  • 28U 통합된 외부 전력 캐비닛 직진 시스템 UPS 배터리 에너지 저장 장

    28U 융합된 외부 전력 캐비닛 및 수정 시스템 UPS 배터리 에너지 저장 1짧은 소개: 야외 통신 캐비닛은 일반적으로 통신 장비의 보호 및 기능을 보장하기 위해 다양한 기능을 갖추고 있습니다. 야외 통신 캐비닛의 몇 가지 일반적인 특징은 다음과 같습니다. 날씨 에 견딜 수 있는 설계: 야외 의 캐비닛 은 비, 눈, 극단적 인 온도, 먼지 와 같은 혹독 한 날씨 에 견딜 수 있도록 설계 되었습니다.그들은 일반적으로 스테인리스 스틸 또는 알루미늄과 같은 내구성 물질로 만들어지며 물과 먼지에 대한 보호 수준을 표시하기 위해 IP (영...
  • 옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각

    옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각 1. 설명 캐비닛은 하나의 구획 캐비닛입니다.캐비닛 냉각은 에어컨과 열교환기를 사용하여 장비가 안정적인 온도 범위에서 정상적으로 작동하도록 하여 장비의 수명을 훨씬 더 길고 성능을 더 안정적으로 만듭니다. 2. 신청 DDTE069 야외 통신 장비 캐비닛은 주로 4G 시스템, 통신/네트워크 통합 서비스, 액세스/전송 스위칭 스테이션, 비상 통신/전송 등과 같은 무선 통신 기지국에 사용됩니다. 3. 빨리 세부 원산지: 중국 심천(본토) 외형 치수: H×W×D 2100×900...
  • 온도 조종 발전기 소켓을 가진 옥외 통신 내각 IP55 진입 보호

    온도 조종 발전기 소켓을 가진 옥외 힘 내각/옥외 통신 내각 1. 사양 (1) 기술적인 매개변수 침투 보호: IP55 등급 B 낙뢰 증거: 공칭: 60KA, 최대: 100KA 온도: 작동 온도: -40°C ~ +55°C 보관 온도: -50°C ~ + 70°C 운송 온도: -50°C ~ +70°C 상대 습도: 5% ~ 100% 기압: 62kpa ~ 101kpa (0m ~ 5000m 고도와 유사) 태양 복사: 1120 ×(1±5%)W/m2 (2) 액세서리 목록 아니요. 안건 수량 단위 명세서 1 야외 전원 캐비닛 1 세트 (1) 외형 ...
  • Emerson 정류기/배터리 옥외 전원 내각 샌드위치 구조 패널 IP55

    에머슨 정류기와 배터리와 샌드위치 구조 패널 야외 전력 소모품 캐비닛 1 제품 설명 1.1 출현 상자가 형태 1과 형태 2에 나타난 바와 같이, 설치된 후 형태 1 형태 2 1.2 캐비닛 설정 이 프로젝트의 야외 통합된 캐비닛 설정은 다음과 같습니다 : 캐비닛 형태 구성 양 상술 주요 캐비닛 19 인치 표준 랙 1 31U 전지 홀더 1 1 층 W×D×H 800×800×350 밀리미터 조명 1 LED 라이트인 48V DC 에어콘 1 AC 220V 입력, 냉각 용량 1500W 에어콘 1 DC 48V 입력, 냉각 용량 300W 접지 구리 ...

문의 를 보내십시오