logo
환영합니다 ESTEL (GUANGDONG) TECHNOLOGY CO., LTD.
+8613752765943 / 86-0755 23592644

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution

기본 특성
원산지: 중국
브랜드 이름: ESTEL
인증: CE UL FCC
부동산 거래
최소 주문 수량: 1세트
가격: USD300-USD1000
지불 조건: T/T, 서부 동맹
공급능력: 5000
제품 요약
ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact ...

제품 상세정보

강조하다:

48V telecom power system with 300A

,

5U 18kW DC power system

,

telecom power system with rectifiers

Solar Array: 24pcs 580W 태양 전지 패널
Input Capacity: 1 × 63A/2p
Thd: 저항 부하에서 <1,5 %
Dc Load Breakers: 30 위치
Efficiency: ≥ 90%
Certifications: ISO9001, CE, 로에스
Package: 판지
Poweroutput: 10kW - 100kW
Ac Frequency: 50Hz, 60Hz 또는 마지막 동기화
Load Protection: LLVD, BLVD
Protectionfeatures: 과전압, 과전류, 단락, 과열
Dc Current Max: 53.5 VDC / 43 - 58 VDC
Dc Output Breakers: 4
Frequency: 45 ∼ 66 Hz
Industrial Ac Input: 각 정류기의 단일 단계
제품 설명

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution

 
 
The ET48300-005 is a 5U rack-mounted DC telecom power system developed for communication sites that need dependable -48V power, organized load distribution and battery backup in a compact cabinet space. It is positioned as an 18kW / 300A class solution, using six 3kW rectifier modules to provide stable DC output for transmission equipment, access devices, switches and base-station loads.
 
This model is suitable for sites using 220VAC single-phase input, making it easier to deploy in equipment rooms or access network cabinets where three-phase power is not available. The system integrates AC input protection, AC surge protection, rectification, battery breakers, LLVD/BLVD load outputs, DC SPD, LCD monitoring and communication terminals into one front-service platform. The front panel layout allows technicians to check breaker status, controller alarms and wiring terminals without removing the system from the rack.

Product Features 18kW 48V 300A DC Telecom Power System

 

18kW modular capacity: Six 3kW rectifiers support flexible configuration and online maintenance.

 

300A DC output class: Suitable for medium to high-load telecom power distribution.

 

Single-phase AC input: Designed for 220VAC sites with 1 × 100A/2P input protection.

 

Clear load separation: LLVD and BLVD branches help divide priority and non-priority equipment.

 

Battery protection: Two 125A battery breakers support backup battery connection and isolation.

 

Surge protection: Integrated AC SPD and DC SPD improve system resistance to transient overvoltage.

 

Remote monitoring support: LCD controller with RS485, SNMP, dry contacts, AI/DI signal inputs.

 

Front maintenance design: Rectifier and controller are hot-pluggable for faster field replacement.

 

Application Scenarios 18kW 48V 300A DC Telecom Power System

 
The ET48300-005 is suitable for wireless base stations, transmission networks, fiber access sites, enterprise communication rooms, microwave stations, telecom cabinets and backup DC power systems requiring stable -48V distribution with battery management.
 

Technical Parameters 18kW 48V 300A DC Telecom Power System

 

Model: ET48300-005

 

Type: 3–18kW 5U Subrack

 

Maximum Current: 300A

 

Dimensions: 482.0(W) × 350.6(D) × 5U(H)

 

Weight: ≤22kg without rectifiers

 

Installation: 19-inch rack or cabinet

 

Cabling: Top inlet and top outlet

 

Protection Level: IP20

 

AC Input: 220VAC single phase

 

Input Capacity: 1 × 100A/2P

 

Frequency: 45–65Hz, rated 50/60Hz

 

AC SPD: 20kA/40kA, 8/20μs

 

DC Output: -43V to -58VDC, rated -53.5VDC

 

Maximum Capacity: 18kW, 6 × 3kW

 

Battery Breakers: 2 × 125A/1P

 

LLVD: 2 × 32A/1P + 2 × 40A/1P + 3 × 63A/1P

 

BLVD: 2 × 6A/1P + 2 × 10A/1P + 2 × 16A/1P

 

DC SPD: 10kA/20kA, 8/20μs

 

Rectifier Efficiency: >96%

 

Power Factor: ≥0.99

 

Operating Temperature: -40°C to +75°C

 

Humidity: 5%–95%, non-condensing

 

Altitude: 0–4000m

 

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 0

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 1

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 2

ET48300005 5U 18kW 48V 300A DC Telecom Power System with Six 3kW Rectifiers and Front Service Distribution 3

관련 상품
  • 28U 통합된 외부 전력 캐비닛 직진 시스템 UPS 배터리 에너지 저장 장

    28U 융합된 외부 전력 캐비닛 및 수정 시스템 UPS 배터리 에너지 저장 1짧은 소개: 야외 통신 캐비닛은 일반적으로 통신 장비의 보호 및 기능을 보장하기 위해 다양한 기능을 갖추고 있습니다. 야외 통신 캐비닛의 몇 가지 일반적인 특징은 다음과 같습니다. 날씨 에 견딜 수 있는 설계: 야외 의 캐비닛 은 비, 눈, 극단적 인 온도, 먼지 와 같은 혹독 한 날씨 에 견딜 수 있도록 설계 되었습니다.그들은 일반적으로 스테인리스 스틸 또는 알루미늄과 같은 내구성 물질로 만들어지며 물과 먼지에 대한 보호 수준을 표시하기 위해 IP (영...
  • 옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각

    옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각 1. 설명 캐비닛은 하나의 구획 캐비닛입니다.캐비닛 냉각은 에어컨과 열교환기를 사용하여 장비가 안정적인 온도 범위에서 정상적으로 작동하도록 하여 장비의 수명을 훨씬 더 길고 성능을 더 안정적으로 만듭니다. 2. 신청 DDTE069 야외 통신 장비 캐비닛은 주로 4G 시스템, 통신/네트워크 통합 서비스, 액세스/전송 스위칭 스테이션, 비상 통신/전송 등과 같은 무선 통신 기지국에 사용됩니다. 3. 빨리 세부 원산지: 중국 심천(본토) 외형 치수: H×W×D 2100×900...
  • 온도 조종 발전기 소켓을 가진 옥외 통신 내각 IP55 진입 보호

    온도 조종 발전기 소켓을 가진 옥외 힘 내각/옥외 통신 내각 1. 사양 (1) 기술적인 매개변수 침투 보호: IP55 등급 B 낙뢰 증거: 공칭: 60KA, 최대: 100KA 온도: 작동 온도: -40°C ~ +55°C 보관 온도: -50°C ~ + 70°C 운송 온도: -50°C ~ +70°C 상대 습도: 5% ~ 100% 기압: 62kpa ~ 101kpa (0m ~ 5000m 고도와 유사) 태양 복사: 1120 ×(1±5%)W/m2 (2) 액세서리 목록 아니요. 안건 수량 단위 명세서 1 야외 전원 캐비닛 1 세트 (1) 외형 ...
  • Emerson 정류기/배터리 옥외 전원 내각 샌드위치 구조 패널 IP55

    에머슨 정류기와 배터리와 샌드위치 구조 패널 야외 전력 소모품 캐비닛 1 제품 설명 1.1 출현 상자가 형태 1과 형태 2에 나타난 바와 같이, 설치된 후 형태 1 형태 2 1.2 캐비닛 설정 이 프로젝트의 야외 통합된 캐비닛 설정은 다음과 같습니다 : 캐비닛 형태 구성 양 상술 주요 캐비닛 19 인치 표준 랙 1 31U 전지 홀더 1 1 층 W×D×H 800×800×350 밀리미터 조명 1 LED 라이트인 48V DC 에어콘 1 AC 220V 입력, 냉각 용량 1500W 에어콘 1 DC 48V 입력, 냉각 용량 300W 접지 구리 ...

문의 를 보내십시오