Customized 12kw 48VDC Power Distribution System with Load Protection Introduction of 12kw 48VDC Power Distribution System The 12kW 48VDC power distribution system is a highly customized, integrated rectifier solution specifically developed for telecom applications where cabinet space is at a premium...

제품 상세정보

강조하다:

12kw 48VDC power distribution system

,

Customized telecom rectifier system

,

Load protection power distribution

Rectifier Type: 통신 전력 분배 장치
AC Power Input: 380VAC 3상, 63A
DC Output Voltage: -48Vdc
Output Capacity: 최대 12kw, N+1 이중화
Rectifier Module: 3000w x 4개
Load Protection: LLVD, BLVD, BATT
Controller: MC2600, 실시간 모니터링
Maintenance: 전면 유지 보수
제품 설명

 

 

Customized 12kw 48VDC Power Distribution System with Load Protection

 

 

Introduction of 12kw 48VDC Power Distribution System

 

The 12kW 48VDC power distribution system is a highly customized, integrated rectifier solution specifically developed for telecom applications where cabinet space is at a premium. Through meticulous mechanical engineering—strategically repositioning the miniature circuit breakers (MCBs), rectifier modules, and controller within the chassis—the system achieves a compact 4U form factor that saves a full 1U of rack space compared to conventional 5U designs. This space-efficient layout liberates valuable cabinet real estate for additional transmission, switching, or auxiliary equipment, without compromising accessibility or serviceability. All critical components remain easily reachable for routine maintenance and module hot-swapping, ensuring that the reduced footprint has no adverse impact on operational convenience or system reliability.

 

For the better AC power performance, the 12kw 48VDC power distribution system adopts three single-pole MCBs and a neutral terminal block for AC input, this configuration offers enhanced reliability and serviceability by using separate 1P MCB per phase. When a fault occurs on one phase, it doesn't shut down the entire system, while keeping the neutral unswitched via a terminal block and ensuring a stable, safe return path and avoids broken neutral hazards. The tiered load protection provides selective fault isolation—so a problem in one branch doesn't affect others—and allows flexible maintenance without total system downtime, all in a cost-effective, space-saving 1P breaker design.

 

Customized 12kw 48VDC Power Distribution System with Load Protection 0

 

Maintenance of 12kw 48VDC Power Distribution System

 

This rectifier features a top-entry, top-exit wiring layout, which minimizes rear clearance requirements—only a small gap is needed for airflow, while cable routing takes up no extra depth. Front only access allows full maintenance without opening a rear cabinet door, significantly reducing overall cabinet footprint, size, and manufacturing cost.

 

Customized 12kw 48VDC Power Distribution System with Load Protection 1

 

Technical Data of 12kw 48VDC Power Distribution System

Item Specification
Type 12kw 48VDC Power Distribution System
Power Input 380VAC three phase
Output Voltage 48VDC
Output Power Up to 12 kW (N+1 redundancy), depends on actual demand
Load Protection

LLVD: 2*10A/1P+2*6A/1P

BLVD: 4*32A/1P+2*32A/1P

BATT: 2*125A/1P

Rectifier Module

Input voltage: 85VAC~300VAC, rated 220VAC

Output capacity: 3000W (176~300VAC)

Efficiency: >96%

Power factor: ≥0.99

THD: ≤5%

DC output: -43 ~ –58VDC, rated –53.5VDC, 55A maximum

Monitoring Unit

Model: MC2600

Signal input: 3 AI (2 ambient + 1 environment, 8 DI)

Alarm output: 8 DO

Display: LCD screen

Communication Port 1*LAN port, 1*RS485 port, SNMP protocol supported
Application

Telecom base stations

Data center UPS systems

Industrial automation production lines

Solar energy storage systems

Railway signalling power supplies

 

Customized 12kw 48VDC Power Distribution System with Load Protection 2

관련 상품
  • 28U 통합된 외부 전력 캐비닛 직진 시스템 UPS 배터리 에너지 저장 장

    28U 융합된 외부 전력 캐비닛 및 수정 시스템 UPS 배터리 에너지 저장 1짧은 소개: 야외 통신 캐비닛은 일반적으로 통신 장비의 보호 및 기능을 보장하기 위해 다양한 기능을 갖추고 있습니다. 야외 통신 캐비닛의 몇 가지 일반적인 특징은 다음과 같습니다. 날씨 에 견딜 수 있는 설계: 야외 의 캐비닛 은 비, 눈, 극단적 인 온도, 먼지 와 같은 혹독 한 날씨 에 견딜 수 있도록 설계 되었습니다.그들은 일반적으로 스테인리스 스틸 또는 알루미늄과 같은 내구성 물질로 만들어지며 물과 먼지에 대한 보호 수준을 표시하기 위해 IP (영...
  • 옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각

    옥외 힘 내각, 물 감지기/문 감지기를 가진 옥외 통신 내각 1. 설명 캐비닛은 하나의 구획 캐비닛입니다.캐비닛 냉각은 에어컨과 열교환기를 사용하여 장비가 안정적인 온도 범위에서 정상적으로 작동하도록 하여 장비의 수명을 훨씬 더 길고 성능을 더 안정적으로 만듭니다. 2. 신청 DDTE069 야외 통신 장비 캐비닛은 주로 4G 시스템, 통신/네트워크 통합 서비스, 액세스/전송 스위칭 스테이션, 비상 통신/전송 등과 같은 무선 통신 기지국에 사용됩니다. 3. 빨리 세부 원산지: 중국 심천(본토) 외형 치수: H×W×D 2100×900...
  • 온도 조종 발전기 소켓을 가진 옥외 통신 내각 IP55 진입 보호

    온도 조종 발전기 소켓을 가진 옥외 힘 내각/옥외 통신 내각 1. 사양 (1) 기술적인 매개변수 침투 보호: IP55 등급 B 낙뢰 증거: 공칭: 60KA, 최대: 100KA 온도: 작동 온도: -40°C ~ +55°C 보관 온도: -50°C ~ + 70°C 운송 온도: -50°C ~ +70°C 상대 습도: 5% ~ 100% 기압: 62kpa ~ 101kpa (0m ~ 5000m 고도와 유사) 태양 복사: 1120 ×(1±5%)W/m2 (2) 액세서리 목록 아니요. 안건 수량 단위 명세서 1 야외 전원 캐비닛 1 세트 (1) 외형 ...
  • Emerson 정류기/배터리 옥외 전원 내각 샌드위치 구조 패널 IP55

    에머슨 정류기와 배터리와 샌드위치 구조 패널 야외 전력 소모품 캐비닛 1 제품 설명 1.1 출현 상자가 형태 1과 형태 2에 나타난 바와 같이, 설치된 후 형태 1 형태 2 1.2 캐비닛 설정 이 프로젝트의 야외 통합된 캐비닛 설정은 다음과 같습니다 : 캐비닛 형태 구성 양 상술 주요 캐비닛 19 인치 표준 랙 1 31U 전지 홀더 1 1 층 W×D×H 800×800×350 밀리미터 조명 1 LED 라이트인 48V DC 에어콘 1 AC 220V 입력, 냉각 용량 1500W 에어콘 1 DC 48V 입력, 냉각 용량 300W 접지 구리 ...

문의 를 보내십시오